latent_heat_of_vaporization#

hydrometlib.evapotranspiration.latent_heat_of_vaporization(ta)[source]#

Latent heat of vaporization (lambda) [MJ kg-1]

\[\lambda = 2.501 - 2.361 \times 10^{-3} \, T_a\]

References

  • Harrison, L.P. 1963. “Fundamental concepts and definitions relating to humidity.” In: Wexler, A. & Wildhack, W.A. (eds.) Humidity and Moisture. Vol. 3. Reinhold Publishing Company, New York

  • FAO-56 Annex 3 https://www.fao.org/4/x0490e/x0490e0k.htm

Parameters:

ta (Expr) – Air temperature [degC]

Return type:

Expr

Returns:

Expression or Series to calculate lambda